ROCKWOOL Limited
Bridgend
Pencoed
CF35 6NY
United Kingdom
Tel:01656 868223
Fax:01656 860302
Email:elian.jones@rockwool.com
Certificate number: KM 06661
Description: Insulation; RW4 Black tissue faced; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 200
Standard | Model No | Branded As |
---|---|---|
BS EN 13162:2012+A1:2015 | MW-EN13162-T4 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW4 White tissue faced; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW6 Foil faced; Thermal Conductivity (W/mK) - 0.035; Reaction to Fire Class - A1; Thickness Range (mm) - 30 - 120 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Cladding Roll; Thermal Conductivity (W/mK) - RWA45 Black tissue faced; Reaction to Fire Class - A1; Thickness Range (mm) - 60 - 220 | BS EN 13162:2012+A1:2015 | MW–EN13162–T1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW128 White tissue face; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 130 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW7 White tissue faced; Thermal Conductivity (W/mK) - 0.037; Reaction to Fire Class - A1; Thickness Range (mm) - 25 – 75 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Rockwool Roll; Thermal Conductivity (W/mK) - 0.044; Reaction to Fire Class - A1; Thickness Range (mm) - 100 - 170 | BS EN 13162:2012+A1:2015 | MW–EN13162–T1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW4 Foil faced; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW6; Thermal Conductivity (W/mK) - 0.035; Reaction to Fire Class - A1; Thickness Range (mm) - 30 - 120 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Timber Frame Slab; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T3-MU1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Cladding Roll-Foil faced; Thermal Conductivity (W/mK) - RWA45 Black tissue faced; Reaction to Fire Class - A1; Thickness Range (mm) - 60 - 220 | BS EN 13162:2012+A1:2015 | MW–EN13162–T1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW128 Black tissue face; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 130 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW7 Black tissue faced; Thermal Conductivity (W/mK) - 0.037; Reaction to Fire Class - A1; Thickness Range (mm) - 25 – 75 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW5 Black tissue faced; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 – 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW128 Foil faced; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 130 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Rockwool Flexi; Thermal Conductivity (W/mK) - 0.035; Reaction to Fire Class - A1; Thickness Range (mm) - 140 – 200 | BS EN 13162:2012+A1:2015 | MW–EN13162–T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW4; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW6 White tissue faced; Thermal Conductivity (W/mK) - 0.035; Reaction to Fire Class - A1; Thickness Range (mm) - 30 - 120 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW7 Foil faced; Thermal Conductivity (W/mK) - 0.037; Reaction to Fire Class - A1; Thickness Range (mm) - 25 – 75 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Rockwool Cavity; Thermal Conductivity (W/mK) - 0.037; Reaction to Fire Class - A1; Thickness Range (mm) - 50 – 200 | BS EN 13162:2012+A1:2015 | MW–EN13162–T2-WS-WL(P) | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW3 White tissue faced; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 23 - 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RWA45 White tissue faced; Thermal Conductivity (W/mK) - 0.035; Reaction to Fire Class - A1; Thickness Range (mm) - 25 – 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW6 Black tissue faced; Thermal Conductivity (W/mK) - 0.035; Reaction to Fire Class - A1; Thickness Range (mm) - 30 - 120 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW5 Foil faced; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 – 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Rockwool Twin Roll; Thermal Conductivity (W/mK) - 0.044; Reaction to Fire Class - A1; Thickness Range (mm) - 100 - 170 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Thermal Insulation Cavity Batt; Thermal Conductivity (W/mK) - 0.044; Reaction to Fire Class - A1; Thickness Range (mm) - 50 – 250 | BS EN 13162:2012+A1:2015 | MW-EN13162-T2-WS-WL(P)-MU1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Thermal Insulation Slab; Thermal Conductivity (W/mK) - 0.044; Reaction to Fire Class - A1; Thickness Range (mm) - 140 – 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4-MU1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Rockwool Flexi; Thermal Conductivity (W/mK) - 0.038; Reaction to Fire Class - A1; Thickness Range (mm) - 50 - 120 | BS EN 13162:2012+A1:2015 | MW–EN13162–T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW128; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 130 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW3 Black tissue faced; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 23 - 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW5 White tissue faced; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 – 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RWA45 Black tissue faced; Thermal Conductivity (W/mK) - 0.035; Reaction to Fire Class - A1; Thickness Range (mm) - 25 – 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW7; Thermal Conductivity (W/mK) - 0.037; Reaction to Fire Class - A1; Thickness Range (mm) - 25 – 75 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Steel Frame Slab; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T3-MU1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Sound Insulation Slab; Thermal Conductivity (W/mK) - 0.035; Reaction to Fire Class - A1; Thickness Range (mm) - 140 – 200 | BS EN 13162:2012+A1:2015 | MW–EN13162–T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Thermal Insulation Roll; Thermal Conductivity (W/mK) - 0.044; Reaction to Fire Class - A1; Thickness Range (mm) - 100 – 220 | BS EN 13162:2012+A1:2015 | MW-EN13162-T1-MU1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; NPower DIY Roll; Thermal Conductivity (W/mK) - 0.044; Reaction to Fire Class - A1; Thickness Range (mm) - 100 - 170 | BS EN 13162:2012+A1:2015 | MW–EN13162–T1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RWA45; Thermal Conductivity (W/mK) - 0.035; Reaction to Fire Class - A1; Thickness Range (mm) - 25 – 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW3; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 23 - 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Thermal Frame Slab; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T3-MU1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; SSE DIY Roll; Thermal Conductivity (W/mK) - 0.044; Reaction to Fire Class - A1; Thickness Range (mm) - 100 - 170 | BS EN 13162:2012+A1:2015 | MW–EN13162–T1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW3 Foil faced; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 23 - 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RollBatt; Thermal Conductivity (W/mK) - 0.044; Reaction to Fire Class - A1; Thickness Range (mm) - 100 - 170 | BS EN 13162:2012+A1:2015 | MW–EN13162–T1 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RW5; Thermal Conductivity (W/mK) - 0.034; Reaction to Fire Class - A1; Thickness Range (mm) - 25 - 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; RWA45 Foil faced; Thermal Conductivity (W/mK) - 0.035; Reaction to Fire Class - A1; Thickness Range (mm) - 25 – 200 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4 | KM 06661 |
Description | Standard | Model No | Certificate Number | Branded As |
---|---|---|---|---|
Insulation; Sound Insulation Slab; Thermal Conductivity (W/mK) - 0.038; Reaction to Fire Class - A1; Thickness Range (mm) - 50 – 120 | BS EN 13162:2012+A1:2015 | MW-EN13162-T4-MU1 | KM 06661 |