AS/NZS 5263.0:2023 Transition

Transition of AS/NZS 5263.0:2023 standard for Australian certification

AS/NZS 5263.0:2017+A1:2020 was superseded in June 2023 and replaced with AS/NZS 5263.0:2023 Gas appliances Part 0: General requirements.

AS/NZS 5263.0:2023 contains minimum requirements for safety, performance and use common to many gas appliances.

AS/NZS 5263.0:2023 used in conjunction with the appliance-specific part (Part 1.X) of the AS/NZS 5263 series are the normative standards in Australia and New Zealand to evaluate and certify gas appliances and equipment intended for domestic, commercial, or light industrial use with an energy limit of 1000 MJ/h.

What technical changes have been made?

Many changes have been made to AS/NZS 5263.0:2023 version, and it is recommended review the new standard to be sure you do not miss any changes that could have significance for your products.

In practice, however, the most significant changes to the standard are:

  • Requirements for appliances incorporating gas/air ratio controls added.
  • Requirements for vibration resistance for appliances suitable for boat and caravan installations.
  • Additional temperature hazards requirements for appliances with air circulating fans.
  • New terms and definitions.
  • Updated requirements for;
  • Gas pressure measurement
  • Guarding fan impellers
  • Provision of regulators
  • Design of flue connection
  • Requirement for burners with granular media
  • Hose assembly classification
  • Flame tracking on ignition
  • Labelling and markings, including new markings for open flued appliances and for appliances suitable for boat and caravan installations
  • Servicing instructions now required to include a maintenance schedule.

Various test methods have been updated for minor corrections and improved clarity – refer to Preface summary in AS/NZS 5263.0:2023.


What gas appliances will be affected?

An appliance specific part (Part 1.X) of the AS/NZS 5263 series, may supplement or modify the corresponding clauses of Part 0. The numbering of clauses in Part 1.X is consistent with the numbering in Part 0 for related requirements.

The appliance specific standards and type of appliances which supplement or modify the corresponding requirements of AS/NZS 5263.0 are:

  • AS/NZS 5263.0 Gas appliances – General requirements
  • AS/NZS 5263.1.1 Gas appliances – Domestic gas cooking appliances
  • AS/NZS 5263.1.2 Gas appliances – Gas fired water heaters for hot water supply and/or central heating
  • AS/NZS 5263.1.3 Gas appliances – Gas space heating appliances
  • AS/NZS 5263.1.4 Gas appliances – Gas appliances radiant gas heaters
  • AS/NZS 5263.1.5 Gas appliances – Domestic gas refrigerators
  • AS/NZS 5263.1.6 Gas appliances – Indirect gas-fired ducted air heaters
  • AS/NZS 5263.1.7 Gas appliances – Domestic outdoor gas barbecues
  • AS/NZS 5263.1.8 Gas appliances – Decorative effect gas appliances
  • AS/NZS 5263.1.9 Gas appliances – Gas laundry dryers
  • AS/NZS 5263.1.10 Gas appliances – Gas direct fired air heaters
  • AS/NZS 5263.1.11 Gas appliances – Small gas engine driven appliances
  • AS/NZS 5263.1.12 Gas appliances – Gas pool heaters
  • AS/NZS 2658 LP Gas – Portable and mobile appliances 
  • AS 4563 Commercial catering gas equipment
  • PP 1540 Gas Fired Humidifier (AGS)
  • AG 112 Approval requirements for incinerating toilets
  • AS 4617 Manually operated gas valves
  • AS 4618 Gas appliance regulators
  • AS 4619 Gas appliance thermostats
  • AS 4620 Thermoelectric flame safeguards
  • AS 4621 Regulators for use with liquefied petroleum gases – vapour phase
  • AS 4622 Electrical and electronic ignition devices for gas appliances
  • AS 4623 Jointing compounds and materials for use in gas pipe joints
  • AS 4624 Combination controls for gas
  • AS 4625 Electronic flame safeguards and flame detectors
  • AS 4627 Quick-connect devices for gas
  • AS 4628 Pressure and temperature limit devices for use with gas burners
  • AS 4629.1 Automatically operated valves for use with gas Shut-off valves
  • AS 4629.2 Automatically operated valves for use with gas Vent valves
  • AS 4630 Leakage detection systems
  • AS 4631 Limited flexibility connectors for gas
  • AS 4632 Over-pressure and under-pressure cut off devices
  • AS 4566 Flue cowls – gas appliances
  • AS 4567 Twin wall metal flues – gas appliances
  • AS 2473.1 Valves for compressed gas cylinders Specifications, type testing, and manufacturing tests and inspections
  • AS 2473.2 Valves for compressed gas cylinders Outlet connections (threaded) and stem (inlet) threads
  • AS 2473.3 Valves for compressed gas cylinders Outlet connections for medical gases (including pin-indexed yoke connections)
  • AG 805 Natural gas vehicle components
  • AG 806 Vehicle refuelling appliances
  • AG 807 Natural gas flexible hose assemblies above 2.6 MPa  
  • AS 1869.0:2023 Hose and hose assemblies for liquefied petroleum gases (LP Gas), natural gas and town gas, Part 0: General requirements
  • AS 1869.1:2023 Hose and hose assemblies for liquefied petroleum gases (LP Gas), natural gas and town gas, Part 1: Non-metallic liners
  • AS 1869.2:2023 Hose and hose assemblies for liquefied petroleum gases (LP Gas), natural gas and town gas, Part 2: Metallic liners
  • AS/NZS 1425 LP Gas fuel systems for vehicle engines
  • EN 298 Automatic burner control systems for burners and appliances burning gaseous or liquid fuels